THE ORIGINAL MAGNETIC PARTICLE SPECIALISTS
Buy direct! Call or email today for a quote!
service@magne-power.com   888-776-2463

MagneClutch 5MC90B Image
  • MagneClutch 5MC90B Image 2
  • MagneClutch 5MC90B Image
  • MagneClutch 5MC90B Image 3
  • MagneClutch 5MC90B Image 4

5 lb. ft. MagneClutch (5MC90B)

SEE TABS BELOW FOR SPECS & RESOURCES

Multiple Options.

  • 90 Volt. Available in other voltages to order.
  • Choice of torque ratings.
  • Water or forced air cooled.

Small Size & Weight.

  • Size tailored to application.
  • Simpler handling & mounting.

Efficient Configuration.

  • Base-mount unit may be used as jack shaft.
  • Received ready to use.
  • Direct coupling to drive or load.

Flexibility.

  • Use as brake or clutch in reeling applications.
  • Wind-unwind tension control.
  • Adapts to production fixtures.
  • Soft acceleration control for delicate materials.

Repair Service Request Form

Multiple Options.

  • 90 Volt. Available in other voltages to order.
  • Choice of torque ratings.
  • Water or forced air cooled.

Small Size & Weight.

  • Size tailored to application.
  • Simpler handling & mounting.

Efficient Configuration.

  • Base-mount unit may be used as jack shaft.
  • Received ready to use.
  • Direct coupling to drive or load.

Flexibility.

  • Use as brake or clutch in reeling applications.
  • Wind-unwind tension control.
  • Adapts to production fixtures.
  • Soft acceleration control for delicate materials.
Model 5MC90B

Data sheet

Model
5MC90B
Rated Torque (lb.-ft.)
5
Mounting
Base
Type Of Cooling
Convection
Heat Dissipation at 1800 RPM (Watts) (5)
136
Max Oper. Speed (RPM) (6)
6000
Non-Excited Drag Torque (lb.-ft.)
0.05
Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - OUTER
0.75
Inertia (WK (2)) Rotating Member (lb.-ft. (2)) x 10(-2) - INNER
0.91
Wgt. Approx (lbs.)
15
Coil Data (Input 90VDC) - CURRENT AMPERES (4)
0.21
Coil Data (Input 90VDC) - RESISTANCE OHMS @ 20 C
306
Note (4)
Coils for other voltages wound to order
Note (5)
The data given represents the average, continuous dissipation capacity of units operating under slip conditions
Note (6)
Applications requiring continuous operation below 30 RPM should be referred to factory for evaluation

Download

**MC90B Installation & Maint.

5MC90B / 10MC(*)90B Installation & Maintenance Manual

Download (200.07k)



**MC90B Service Parts Info.

5MC**B / 10MC(*)**B Service Parts Information Manual

Download (1.89M)



5MC90B Spec. Drawing

5MC90B Engineering Drawing 2940447

Download (2.39M)